IPC12-30Pilot-operated Check Valve (Two-stage opening type)
Product Details
Product Description
Threaded cartridge pilot-operated check valve for one-way shut-off or load-holding circuits. The pressure-reducing function is locked within a controllable range, reducing high energy consumption of the high-pressure control circuit and the large hydraulic shock when the check valve opens in reverse.
Working Principle
Allows flow from ② to ① while blocking reverse flow. When the pressure at ③ reaches a certain value, a small amount of oil flows from ① to , relieving the load pressure on port ①; as the load pressure decreases, the pilot pressure required to open the main stage also drops, and once sufficient, flow passes fully from ① to ②. The reduction ratio is 25:1 and the pilot ratio 3:1. Under static or no-load conditions, spring pressure keeps the valve seated. Note: any backpressure at port ② adds 1:1 to the calculated pilot pressure.
Symbol & Performance


Installation Dimensions & Ordering Code